# # NetWorker # 7.3.2.Build.364 # EMC Corporation # # SONY ASC/ASCQ Error Codes # 0x29, 0x80, Drive failed power or test or diagnostic 0x04, 0x83, Door is opened ("DOOR OPEN" is lit on the DMS display) 0x04, 0x8d, DMS is in the test mode 0xa0, 0x00, Currently resetting SCSI 0xa1, 0x00, Ejecting 0x80, 0x00, Synchronize error has occurred 0x81, 0x00, Lost lock error has occurred 0x83, 0x00, Abnormal data transmission speed 0x84, 0x00, Parity error between Drive has occurred (Faulty connection of data cable) 0x90, 0x00, Insert a tape which is requested to recover data 0x90, 0x01, Recover failed 0x90, 0x02, Insert an unformatted tape 0x90, 0x03, Attempted to load a cassette that was not unloaded properly the last time 0xfc, 0x00, READ/WRITE done in inhibited area 0x28, 0x8d, Test mode is canceled 0x81, 0x1d, Could not search for window 0x81, 0x1f, Barcode read error 0x81, 0x23, Command was interrupted and ended 0x81, 0x28, Servo went off (SERVO OFF2) 0x81, 0x29, Media size error (MEDIUM SIZE ERROR2) 0x81, 0x2f, Communication with CC is abnormal (DMS-B35 only) 0x81, 0x33, Representative window is not initialized 0x81, 0x35, Drive is pulled out 0x81, 0x36, Outport is full 0x81, 0x3b, Cassette is in the transport element 0x81, 0x3c, Transport element failed to put cassette 0x81, 0x3d, Transport failed to get cassette 0x81, 0x42, Command data format is incorrect 0x81, 0x46, I/O port is used 0x81, 0x48, Servo went off (SERVO OFF1) 0x81, 0x49, Media size error 0x81, 0x4f, Communication with CC is abnormal (DMS-B35 only) 0x81, 0x53, Representative window is not initialized 0x81, 0x55, Drive is pulled out 0x81, 0x56, Output port is full 0x81, 0x59, Cassette type in source element is different from that in destination element 0x81, 0x5a, Specified BIN does not exist 0x81, 0x5b, Cassette is in the transport element 0x81, 0xa7, DMS recognized that the cassette carrier element is not connected 0x81, 0xa8, Communication error occurred between servo unit 0x81, 0xad, Communication error with junction port 0x81, 0xae, Communication error occurred between I/O port 0x81, 0xb0, Detected power failure 0x81, 0xb6, Trouble has occurred in barcode reader 0x81, 0xb7, Malfunction of transport element 0x81, 0xb8, Trouble has occurred in servo of cassette carrier element 0x81, 0xba, Trouble has occurred in destination element 0x81, 0xbb, Trouble has occurred in source element 0x81, 0xbd, Error occurred in junction port 0x81, 0xbe, Trouble has occurred in I/O port 0x81, 0xbf, Cassette is protruded and cassette carrier element cannot be moved 0x81, 0xc7, Transport element is not connected 0x81, 0xc8, Communication error occurred between servo unit 0x81, 0xcd, Communication error with junction port 0x81, 0xce, Communication error occurred between I/O port 0x81, 0xd0, Power is down and cannot execute cassette move command 0x81, 0xd6, Trouble has occurred in barcode reader 0x81, 0xd7, Malfunction of transport 0x81, 0xd8, Trouble has occurred in servo of cassette carrier element 0x81, 0xda, Trouble has occurred in destination element 0x81, 0xdb, Trouble has occurred in source element 0x81, 0xdd, Error occurred in junction port 0x81, 0xde, Trouble has occurred in I/O port 0x81, 0xdf, Cassette is protruded and cassette carrier element cannot be moved 0x81, 0xf9, Macro number is currently in use 0x81, 0xfa, Ended abnormally 0x81, 0xfb, Cassette move command cannot be executed for some reason 0x81, 0xfc, Reception macro reached the allowable number 0x81, 0xfd, Specified macro number does not exist 0x81, 0xfe, Macro has been canceled 0x81, 0xff, Macro has been canceled 0x82, 0x00, Data error(Could not read properly) (Sense Key = 0x03) 0x82, 0x00, Excessive connections or executed commands (Sense Key = 0x09) 0x82, 0x01, Cassette currently in use 0x82, 0x02, Cannot move due absence of bar code 0x82, 0x03, Drive is busy 0x82, 0x04, Communication with drive is not connected 0xff, 0x00, Drive errors 0xff, 0x01, Damaged header area (Sense Key = 0x03) 0xff, 0x01, Other Errors (Sense Key = 0x09)