-- ***************************************************************** -- CISCO-VISM-ATM-TRUNK-MIB -- The MIB contains AAL2 CID (Channel Identifier) -- and also Bearer Connection information -- for VISM (Voice Interworking Service Module). -- -- December 2003, George Ogagan -- April 2004, Rashmi Purandare -- -- Copyright (c) 2003, 2004 by Cisco Systems, Inc. -- All rights reserved. -- **************************************************************** CISCO-VISM-ATM-TRUNK-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32, Unsigned32 FROM SNMPv2-SMI TruthValue FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF voice, vismChanGrp FROM BASIS-MIB ciscoWan FROM CISCOWAN-SMI; ciscoVismAtmTrunkMIB MODULE-IDENTITY LAST-UPDATED "200404140000Z" ORGANIZATION "Cisco Systems, Inc." CONTACT-INFO " Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-wanatm@cisco.com" DESCRIPTION "The MIB module contain the Bearer and CID (Channel Identifier) connection information." REVISION "200404140000Z" DESCRIPTION "Added - bearerPeakXmtCellRate - bearerCurrentXmtCellRate - bearerPeakRcvCellRate - bearerCurrentRcvCellRate - bearerCurrentExtAISRcvCnts - bearerCurrentExtRAIRcvCnts - bearerCurrentConnAISCnts - bearerCurrentConnRDICnts - bearerCurrentExtAISXmtCnts - bearerCurrentExtRAIXmtCnts Statistics for bearer cell rates and alarm counts. " REVISION "200402050000Z" DESCRIPTION "Added - vismAal2CidAdminState " REVISION "200312090000Z" DESCRIPTION "Initial version of the MIB. The content of this MIB was originally available in SMIv1 version. The MIB has been converted to SMIv2 version and descriptions of some of the objects have been modified." ::= { ciscoWan 87 } bearerConnGrp OBJECT IDENTIFIER ::= { voice 9 } vismAal2CidGrp OBJECT IDENTIFIER ::= { vismChanGrp 4 } bearerConnTable OBJECT-TYPE SYNTAX SEQUENCE OF BearerConnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes the statistical information available on a per-bearer connection basis. These values are applicable equally to an endpoint. " ::= { bearerConnGrp 1 } bearerConnEntry OBJECT-TYPE SYNTAX BearerConnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Each entry in this table corresponds to a bearer connection, that was setup by binding an endpoint with a VC(Virtual channel)/CID pair, either through CLI or SNMP. The statistical counters in this table are generic voice quality parameters that are equally applicable in all types of Voice Over Packet adapations (VoIP, VoAAL1 and VoAAL2). However, they are maintained only in the PVC(Permanent virtual circuit) trunking model because, these counters get reset in the switching model on a per call basis. The entries in this table are implicitly created/deleted at the time of creation/deletion of entries in the vismAal2CidCnfTable. " INDEX { bearerEndptNum } ::= { bearerConnTable 1 } BearerConnEntry ::= SEQUENCE { bearerEndptNum Integer32, bearerCid Integer32, bearerLcn Integer32, bearerSentPkts Counter32, bearerRcvdPkts Counter32, bearerSentOctets Counter32, bearerRcvdOctets Counter32, bearerLostPkts Counter32, bearerJitter Integer32, bearerLatency Integer32, bearerAal2ExtAISCnts Counter32, bearerAal2ExtRAICnts Counter32, bearerAal2ConnAISCnts Counter32, bearerAal2ConnRDICnts Counter32, bearerCntClrButton INTEGER, bearerPeakXmtCellRate Unsigned32, bearerCurrentXmtCellRate Unsigned32, bearerPeakRcvCellRate Unsigned32, bearerCurrentRcvCellRate Unsigned32, bearerCurrentExtAISRcvCnts Counter32, bearerCurrentExtRAIRcvCnts Counter32, bearerCurrentConnAISCnts Counter32, bearerCurrentConnRDICnts Counter32, bearerCurrentExtAISXmtCnts Counter32, bearerCurrentExtRAIXmtCnts Counter32 } bearerEndptNum OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the index for the Bearer Connection Table. This refers to the same value as the index to the mgEndpointTable ie. mgEndpointNumber. This is define in CISCO-WAN-MG-MIB MIB. " ::= { bearerConnEntry 1 } bearerCid OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the CID associated with this bearer connection. This refers to the same value as vismAal2CidNum in the vismAal2CidCnfTable. " ::= { bearerConnEntry 2 } bearerLcn OBJECT-TYPE SYNTAX Integer32(131..510) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the PVC or LCN(Logical Channel Number) number to which this bearer connection is associated with. This refers to the same value as in vismCnfChanNum in vismChanCnfGrp table. This is define in CISCO-VISM-CONN-MIB MIB. " ::= { bearerConnEntry 3 } bearerSentPkts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the count of packets sent towards the network since this connection setup. " ::= { bearerConnEntry 4 } bearerRcvdPkts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the count of packets received from the network since this connection setup. " ::= { bearerConnEntry 5 } bearerSentOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the count of bytes sent towards the network since this connection setup. " ::= { bearerConnEntry 6 } bearerRcvdOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the count of bytes received from the network since this connection setup. " ::= { bearerConnEntry 7 } bearerLostPkts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the count of packets lost in the egress direction (from the network). This is a computed number based on the expected number of packets and the actual number of packets arrived from the network. " ::= { bearerConnEntry 8 } bearerJitter OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the jitter (a.k.a interarrival jitter) This value is determined by the DSP(Digital Signal Processing) and obtained by the HOST processor upon querying the DSP on a periodic basis. " ::= { bearerConnEntry 9 } bearerLatency OBJECT-TYPE SYNTAX Integer32 UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines the latency (a.k.a end-to-end average transmission delay for a voice packet). " ::= { bearerConnEntry 10 } bearerAal2ExtAISCnts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " This object contains the number of external AIS (Alarm Indication Signal) AAL2 Type3 packets received. External AIS - is associated with a maintenance alarm detected on a defective maintenance span, that is transmitted in the direction of the defect as a substitute for normal signal. The purpose is to show the downstream entities that a defect has been identified and to prevent other maintenance alrams consequent to this first defect. External AIS bit stream is represented by an all 1's signal. " REFERENCE "ITU-T Rec. M.20 sec. 5.4.2 a" ::= { bearerConnEntry 11 } bearerAal2ExtRAICnts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the number of external RAI (Remote Alarm Indication) AAL2 Type3 packets received. External RAI - is a signal that is transmitted upstream from an entity that has detected defects persisting long enough to constitute a received signal failure. Its purpose is to report in the backward direction that there is an interruption of service in the forward direction. " REFERENCE "ITU-T Rec. G.704 section 2.1.3.1.3" ::= { bearerConnEntry 12 } bearerAal2ConnAISCnts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the number of external Conn AIS AAL2 Type2 packets received. External Conn AIS - is transmitted in the downstream direction from the AAL Type 2 connecting point that first detects a defect affecting the AAL Type 2 connection; this includes defects indicated by lower layers. " REFERENCE "ITU-T Rec. I.610 sec 6.2.2.1.1.1" ::= { bearerConnEntry 13 } bearerAal2ConnRDICnts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " This object contains the number of external Conn RDI(Remote Defect Indication) AAL2 Type2 packets received. External Conn RDI - is a signal transmitted upstream by an AAL Type 2 endpoint that is in an alarm state as the result of having received an AAL Type2 connection AIS or having detected a defect that affects the AAL Type2 connection. " ::= { bearerConnEntry 14 } bearerCntClrButton OBJECT-TYPE SYNTAX INTEGER { noaction(1), clear (2) } MAX-ACCESS read-write STATUS current DESCRIPTION " This object is used to clear bearerSentPkts, bearerRcvdPkts, bearerSentOctets, and bearerRcvdOctets. " ::= { bearerConnEntry 15 } bearerPeakXmtCellRate OBJECT-TYPE SYNTAX Unsigned32 (1..2147483647) UNITS "cells-per-second" MAX-ACCESS read-only STATUS current DESCRIPTION "Peak transmit ATM cell rate is the ATM cells required to transmit peak AAL2 packets on a CID per second since midnight as per system time; the peak cell rate gets cleared every 24 hours at midnight as per system time. " ::= { bearerConnEntry 16 } bearerCurrentXmtCellRate OBJECT-TYPE SYNTAX Unsigned32 (1..2147483647) UNITS "cells-per-second" MAX-ACCESS read-only STATUS current DESCRIPTION "Current transmit ATM cell rate is the ATM cells required to transmit current AAL2 packets on a CID per second. " ::= { bearerConnEntry 17 } bearerPeakRcvCellRate OBJECT-TYPE SYNTAX Unsigned32 (1..2147483647) UNITS "cells-per-second" MAX-ACCESS read-only STATUS current DESCRIPTION "Peak receive ATM cell rate is the ATM cells required to receive peak AAL2 packets on a CID per second since midnight as per system time; the peak cell rate gets cleared every 24 hours at midnight as per system time. " ::= { bearerConnEntry 18 } bearerCurrentRcvCellRate OBJECT-TYPE SYNTAX Unsigned32 (1..2147483647) UNITS "cells-per-second" MAX-ACCESS read-only STATUS current DESCRIPTION "Current receive ATM cell rate is the ATM cells required to receive current AAL2 packets on a CID per second. " ::= { bearerConnEntry 19 } bearerCurrentExtAISRcvCnts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the count of external AIS AAL2 (Type 2) received on this bearerEndptNum since its creation. " ::= { bearerConnEntry 20 } bearerCurrentExtRAIRcvCnts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the number of external RAI AAL2 (Type 2) received in this bearerEndptNum since its creation. " ::= { bearerConnEntry 21} bearerCurrentConnAISCnts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains count of external Connection AIS AAL2 (Type 2) received in this bearerEndptNum since its creation. " ::= { bearerConnEntry 22 } bearerCurrentConnRDICnts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the count of external Connection RDI (Remote Defect Indication) AAL2 (Type 2) received in this bearerEndptNum since its creation. " ::= { bearerConnEntry 23 } bearerCurrentExtAISXmtCnts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the count of external AIS AAL2 (Type 2) transmitted in this bearerEndptNum since its creation. " ::= { bearerConnEntry 24 } bearerCurrentExtRAIXmtCnts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the count of external RAI AAL2 (Type 2) transmitted in this bearerEndptNum since its creation. " ::= { bearerConnEntry 25 } vismAal2CidCnfTable OBJECT-TYPE SYNTAX SEQUENCE OF VismAal2CidEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is defined to establish the binding between an endpoint and a PVC/CID pair in the case of AAL2 adaptation. This table is created and used in trunking mode VISM application only. The maximum number of CIDs that can be configured depends on the current codec template being used as represented by vismAppliedTemplate object. The signaling type of the line has to be configured before adding any CID on that line. " ::= { vismAal2CidGrp 1 } vismAal2CidEntry OBJECT-TYPE SYNTAX VismAal2CidEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Identifies an entry for vismAal2CidCnfTable. " INDEX { vismAal2CidLcn, vismAal2CidNum } ::= { vismAal2CidCnfTable 1 } VismAal2CidEntry ::= SEQUENCE { vismAal2CidNum Integer32, vismAal2CidLcn Integer32, vismAal2EndptNum Integer32, vismAal2CidRowStatus INTEGER, vismAal2CidType3Redundancy TruthValue, vismAal2CidVad TruthValue, vismAal2CidProfileType INTEGER, vismAal2CidProfileNum Integer32, vismAal2CidCodecType INTEGER, vismAal2CidDtmfTransport TruthValue, vismAal2CidCasTransport TruthValue, vismAal2CidEcanEnable TruthValue, vismAal2InitVadTimer Integer32, vismAal2CnfPktPeriod INTEGER, vismAal2CidICSEnable TruthValue, vismAal2CidState INTEGER, vismAal2CidFailReason INTEGER, vismAal2CidAdminState INTEGER } vismAal2CidNum OBJECT-TYPE SYNTAX Integer32 (8..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines part of the index for this table. vismAal2CidNum is the CID of a voice channel. CID has to be the same at both endpoints for a connection. CID is unique only within the context of a Virtual Circuit (PVC or SVC). " ::= { vismAal2CidEntry 1 } vismAal2CidLcn OBJECT-TYPE SYNTAX Integer32 (131..510) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute defines part of the index for the vismAal2CidCnfTable. Since CID is unique to a PVC, a combination of LCN and CID uniquely identifies a voice connection. This field refers to vismCnfChanNum defined in vismChanCnfGrp of CISCO-VISM-CONN-MIB MIB. " ::= { vismAal2CidEntry 2 } vismAal2EndptNum OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute defines the endpoint number to which this CID is associated. It is the same as mgEndpointNumber defined in mgEndpointTable of CISCO-WAN-MG-MIB MIB. " ::= { vismAal2CidEntry 3 } vismAal2CidRowStatus OBJECT-TYPE SYNTAX INTEGER { active (1), createAndGo (4), destroy (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable allows to add or delete a CID. A CID can only be added or deleted. Once added, modifying an entry is not allowed. 'createAndGo': Use this to add an entry in this table. 'active': This values is returned, once the row is created. 'destroy': Use this to delete an entry from this table. " ::= { vismAal2CidEntry 4 } vismAal2CidType3Redundancy OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute defines whether the triple redundancy is supported for type 3 packets in AAL2 for this channel. When Triple redundancy is enabled for a channel, the Type 3 packets (CAS bits, dialled digits and user state control packets) are transmitted in triplicates with an interval defined as per the standards I.366.2. For channels which are quite reliable, triple redundancy can be disabled in order to save the bandwidth and the processing overheads. The default value of this object is 'true(1)' if either vismAal2CidCasTransport or vismAal2CidDtmfTransport is 'true(1)', otherwise the default value is 'false(2)'. " ::= { vismAal2CidEntry 5 } vismAal2CidVad OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute defines whether the VAD (Voice Activity Detection) has to be applied on this channel, upon detection of silence. For algorithms that do not have VAD standards, Cisco-proprietary VAD can be applied and the generic SID(Silence Information Descriptor) packet as specified in I.366.2 standards can be sent to the other end. When the codec specify in vismAal2CidCodecType is 'clearChannel' VAD has to be off. " DEFVAL { false } ::= { vismAal2CidEntry 6 } vismAal2CidProfileType OBJECT-TYPE SYNTAX INTEGER { itu (1), atm (2), custom (3), none (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute defines the profile type. The profile type defines which group of the profile tables the profile number should correspond to. There are three possible groups: 'itu' - corresponding to the tables in ITU format in the profile is being used. 'atm' - This is not supported 'custom' - VISM specific custom profiles. " DEFVAL { custom } ::= { vismAal2CidEntry 7 } vismAal2CidProfileNum OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute defines the profile number. A profile is a set of entries, where each entry specifies an encoding format with a UUI(User-to-User Indication) range and length. This set defines a mapping that informs the receiver of a Type 1 packet how to interpret the packet contents, i.e. which encoding format in the profile is being used. " DEFVAL { 100 } ::= { vismAal2CidEntry 8 } vismAal2CidCodecType OBJECT-TYPE SYNTAX INTEGER { g711u (1), g711a (2), g726r32000 (3), g729a (4), g729ab (5), clearChannel (6), g726r16000 (7), g726r24000 (8), g726r40000 (9), g723h (11), g723ah (12), g723l (13), g723al (14), lossless (15) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute defines the codec Type used for the connection. 'g711u' represents PCMU with 64 kbps. 'g711a' represents PCMA with 64 kbps. 'g726r32000' represents G.726 at rate 32 kbps 'g726r16000' represents G.726 at rate 16 kbps 'g726r24000' represents G.726 at rate 24 kbps 'g726r40000' represents G.726 at rate 40 kbps 'g729a' represents G.729 Annex A algorithm. 'g729ab' represents G.729 Annex A and Annex B algorithm. 'clearChannel' represents CCD with 64 kbps. 'g723h' represents G.723.1-H at rate 6.3kbps. 'g723ah' represents G.723.1-H at rate 6.3kbps with Silence Supression ON. 'g723l' represents G.723.1-L at rate 5.3kbps. 'g723al' represents G.723.1-L at rate 5.3kbps with Silence Supression ON. 'lossless' represents Lossless Note : 1. When codec type is 'clearChannel', vismAal2CidProfileType and vismAal2CidProfileNum are not applicable and will be ignored. 2. Value 10 is RESERVED. " ::= { vismAal2CidEntry 9 } vismAal2CidDtmfTransport OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute defines whether the DTMF (Dual Tone Multi Frequency) digits need to be transported to the other end-point. " DEFVAL { true } ::= { vismAal2CidEntry 10 } vismAal2CidCasTransport OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute defines whether the CAS(Channel Associated Signaling) bits need to be transported to the other endpoint. In the case of switching application, the CAS bits are backhauled to the call agent through xGCP(Gateway Control Protocol)-CAS protocol. Note that if the line signaling type is CAS the default value is 'true(1)', else the default value is 'false(2)'. " ::= { vismAal2CidEntry 11 } vismAal2CidEcanEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute defines whether Echo Cancellation has to be enabled on this connection. If it is set to 'true(1)', echo cancellation is enabled. If it is set to 'false(2)', echo cancellation is disabled. " DEFVAL { true } ::= { vismAal2CidEntry 12 } vismAal2InitVadTimer OBJECT-TYPE SYNTAX Integer32(250..65535) UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute defines the hangover time for VAD. Once the voice inactivity is detected, the gateway will wait for this duration before activating silence suppression. " DEFVAL { 250 } ::= { vismAal2CidEntry 13 } vismAal2CnfPktPeriod OBJECT-TYPE SYNTAX INTEGER { five (5), ten (10), twenty (20), thirty(30), fourty (40) } MAX-ACCESS read-write STATUS current DESCRIPTION " This object is used to configure the packetization period for a given codec. This packetization period has to be a valid entry in the profile table. Profile type and number identify a unique profile table and one codec type in this table might have one or more packetization period. This is applicable only if the vismAal2CidCodecType is 'g729a'. The configurable values for 'g729a' are 10,20,30 & 40. If a CID entry is configured with a codec other than 'g729a' then the user cannot configure the pkt period for that codec and the pkt period is picked from the profile table. Hence when we do get/walk on this entry/table any one of the above values could be returned. " REFERENCE "ITU specification I.366.2 annex P." DEFVAL{ ten } ::= { vismAal2CidEntry 14 } vismAal2CidICSEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION " This object is used to enable or disable the ICS(Idle Channel Suppression) for a CID. This can be specified while adding the CID and cannot be modified. When the Idle Channel Suppression is enabled the DSP will look for the idle CAS (ABCD bits) pattern specified in ds0IdleCode in CISCO-VISM-DSX0-MIB MIB. If the idle pattern is present the DSP stops generating voice packets towards ATM side. By default the ds0IdleCode will be zero unless the user has configured it before adding the CID. If the ds0IdleCode is changed after the CID is added it will have no affect unless the card is reset. ICS is applicable only for trunking application, in case of switching there is no need for ICS as the calls are teared down and set up dynamically. " DEFVAL { false } ::= { vismAal2CidEntry 15 } vismAal2CidState OBJECT-TYPE SYNTAX INTEGER { cidStateActive (1), cidStateFailed (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the state of the CID. 'cidStateActive' : The CID is in service and operational. 'cidStateFailed' : The CID is in service but not operational, e.g. because the PVC that the CID belongs to is receiving F5(Operation, Administration and Maintenance Flow) level alarm. When VISM sees alarm on a CID (network side) sets this object to 'cidStateFailed', and an AIS will be sent on the ds0(Time Division Multiplexed voice channel) that this CID corresponds to. If the whole PVC is in alarm then all the CIDs on that PVC will be set to 'cidStateFailed', trapVismChanFailed trap will be sent and all the ds0's that corresponds to each of the CIDs on this PVC will be in alarm. If VISM sees an alarm on a ds0 in a line then an RAI(Remote Alarm Indication) will be sent on the CID that corresponds to this ds0, however the CID will not be put in failed state. " ::= { vismAal2CidEntry 16 } vismAal2CidFailReason OBJECT-TYPE SYNTAX INTEGER { self (1), highLevel (2), both (3), notFail (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used to indicate the CID failure reason. 'self': fail because of non-PVC alarm 'highLevel': fail because of PVC alarm 'both': fail because of both PVC and non-PVC alarm 'notFail': not fail " DEFVAL { notFail } ::= { vismAal2CidEntry 17 } vismAal2CidAdminState OBJECT-TYPE SYNTAX INTEGER { cidPendingInService (1), cidInService (2), cidCommandedOutOfService (3), cidPendingOutOfService (4), cidUnknownState (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute defines the operational administrative state of the bearer connection. cidInService: This is an operational state of the bearer connection where it is ready to transmit/receive data/voice packets. The user can take the bearer connection into cidInService. cidCommandedOutOfService: This is an operational state of the bearer connection where it is not ready to transmit/receive data/voice packets. The user can take the bearer connection into cidPendingOutOfService. cidPendingInService: It is a transient state. In this state the bearer connection is waiting for the user to transition it to the cidInService state. This value cannot be specified in a management protocol set operation. cidPendingOutOfService: It is a transient state. In this state the bearer connection is waiting for the user to transition it to the cidOutOfService state. This value cannot be specified in a management protocol set operation. cidUnknownState: This is an abnormal state of the bearer connection. This state would indicate to the user that there is some data integrity issue on the bearer administrative state. " DEFVAL { cidPendingInService } ::= { vismAal2CidEntry 18 } -- conformance information cvismAtmTrunkMIBConformance OBJECT IDENTIFIER ::= { ciscoVismAtmTrunkMIB 2 } cvismAtmTrunkMIBGroups OBJECT IDENTIFIER ::= { cvismAtmTrunkMIBConformance 1 } cvismAtmTrunkMIBCompliances OBJECT IDENTIFIER ::= { cvismAtmTrunkMIBConformance 2 } -- compliance statements cvismAtmTrunkCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for objects related to VISM Bearer and CID Connection." MODULE -- this module MANDATORY-GROUPS { ciscoVismBearerConnGroup, ciscoVismAAl2CidGroup } ::= { cvismAtmTrunkMIBCompliances 1 } cvismAtmTrunkComplianceRev1 MODULE-COMPLIANCE STATUS deprecated --Replaced by cvismAtmTrunkComplianceRev2 DESCRIPTION "The compliance statement for objects related to VISM Bearer and CID Connection." MODULE -- this module MANDATORY-GROUPS { ciscoVismBearerConnGroup, ciscoVismAAl2CidGroupRev1 } ::= { cvismAtmTrunkMIBCompliances 2 } cvismAtmTrunkComplianceRev2 MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for objects related to VISM Bearer and CID Connection." MODULE -- this module MANDATORY-GROUPS { ciscoVismBearerConnGroupRev1, ciscoVismAAl2CidGroupRev1 } ::= { cvismAtmTrunkMIBCompliances 3 } ciscoVismBearerConnGroup OBJECT-GROUP OBJECTS { bearerEndptNum, bearerCid, bearerLcn, bearerSentPkts, bearerRcvdPkts, bearerSentOctets, bearerRcvdOctets, bearerLostPkts, bearerJitter, bearerLatency, bearerAal2ExtAISCnts, bearerAal2ExtRAICnts, bearerAal2ConnAISCnts, bearerAal2ConnRDICnts, bearerCntClrButton } STATUS deprecated --Replaced by ciscoVismBearerConnGroupRev1 DESCRIPTION "The collection of objects which are used to represent VISM Bearer connection." ::= { cvismAtmTrunkMIBGroups 1 } ciscoVismAAl2CidGroup OBJECT-GROUP OBJECTS { vismAal2CidNum, vismAal2CidLcn, vismAal2EndptNum, vismAal2CidRowStatus, vismAal2CidType3Redundancy, vismAal2CidVad, vismAal2CidProfileType, vismAal2CidProfileNum, vismAal2CidCodecType, vismAal2CidDtmfTransport, vismAal2CidCasTransport, vismAal2CidEcanEnable, vismAal2InitVadTimer, vismAal2CnfPktPeriod, vismAal2CidICSEnable, vismAal2CidState, vismAal2CidFailReason } STATUS deprecated --replaced by ciscoVismAAl2CidGroupRev1 DESCRIPTION "The collection of objects which are used to represent VISM AAL2 CID connection." ::= { cvismAtmTrunkMIBGroups 2 } ciscoVismAAl2CidGroupRev1 OBJECT-GROUP OBJECTS { vismAal2CidNum, vismAal2CidLcn, vismAal2EndptNum, vismAal2CidRowStatus, vismAal2CidType3Redundancy, vismAal2CidVad, vismAal2CidProfileType, vismAal2CidProfileNum, vismAal2CidCodecType, vismAal2CidDtmfTransport, vismAal2CidCasTransport, vismAal2CidEcanEnable, vismAal2InitVadTimer, vismAal2CnfPktPeriod, vismAal2CidICSEnable, vismAal2CidState, vismAal2CidFailReason, vismAal2CidAdminState } STATUS current DESCRIPTION "The collection of objects which are used to represent VISM AAL2 CID connection." ::= { cvismAtmTrunkMIBGroups 3 } ciscoVismBearerConnGroupRev1 OBJECT-GROUP OBJECTS { bearerEndptNum, bearerCid, bearerLcn, bearerSentPkts, bearerRcvdPkts, bearerSentOctets, bearerRcvdOctets, bearerLostPkts, bearerJitter, bearerLatency, bearerAal2ExtAISCnts, bearerAal2ExtRAICnts, bearerAal2ConnAISCnts, bearerAal2ConnRDICnts, bearerCntClrButton, bearerPeakXmtCellRate, bearerCurrentXmtCellRate, bearerPeakRcvCellRate, bearerCurrentRcvCellRate, bearerCurrentExtAISRcvCnts, bearerCurrentExtRAIRcvCnts, bearerCurrentConnAISCnts, bearerCurrentConnRDICnts, bearerCurrentExtAISXmtCnts, bearerCurrentExtRAIXmtCnts } STATUS current DESCRIPTION "The collection of objects which are used to represent VISM Bearer connection." ::= { cvismAtmTrunkMIBGroups 4 } END