-- ***************************************************************** -- DOCS-TEST-MIB.my: Data Over Cable Test MIB file -- -- Aug 2003 Sajeev Jos -- -- This MIB is from SP-TestMIBv2.0-D02-030530 -- -- Copyright (c) 1999-2003, 2007-2008 by cisco Systems, Inc. -- All rights reserved. -- ***************************************************************** DOCS-TEST-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, -- do not import BITS, Integer32, enterprises FROM SNMPv2-SMI TEXTUAL-CONVENTION, TruthValue FROM SNMPv2-TC OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF; -- These are the defined Cablelabs OID paths. Not all are needed for the Test MIB, -- but included here for sake of completeness. cableLabs OBJECT IDENTIFIER ::= { enterprises 4491 } clabFunction OBJECT IDENTIFIER ::= { cableLabs 1 } clabFuncMib2 OBJECT IDENTIFIER ::= { clabFunction 1 } clabFuncProprietary OBJECT IDENTIFIER ::= { clabFunction 2 } clabProject OBJECT IDENTIFIER ::= { cableLabs 2 } clabProjDocsis OBJECT IDENTIFIER ::= { clabProject 1 } clabProjPacketCable OBJECT IDENTIFIER ::= { clabProject 2 } clabProjOpenCable OBJECT IDENTIFIER ::= { clabProject 3 } clabProjCableHome OBJECT IDENTIFIER ::= { clabProject 4 } docsTestMIB MODULE-IDENTITY LAST-UPDATED "0203150000Z" -- March 15, 2002 ORGANIZATION "DOCSIS 2.0 ATP Working Group" CONTACT-INFO " David Raftus Postal: Terayon Canada Ltd 340 Terry Fox Drive, Suite 202 Ottawa Ontario Canada Phone: +1 613 592 1052 E-mail: david.raftus@terayon.com DOCSIS 2.0 ATP Working Group General Discussion: docsis-20@cablelabs.com, docsis-20-atp@cablelabs.com" DESCRIPTION "This is the MIB Module supporting programmable test features for DOCSIS 2.0 compliant Cable Modems (CM) and Cable Modem Termination Systems (CMTS)." -- 4491 is the IANA Cablelabs enterprise number ::= { clabProjDocsis 12 } -- Textual Conventions -- none required yet - dave - leave as a placeholder -- Mapping path to the test mib. -- docsTestMibObjects OBJECT IDENTIFIER ::= { docsTestMIB 1 } docsTestBaseObjects OBJECT IDENTIFIER ::= { docsTestMibObjects 1 } docsTestSetupObjects OBJECT IDENTIFIER ::= { docsTestMibObjects 2 } -- -- docsTestBaseObjects -- -- These objects indicate the capability and current status of the -- programmable test features on the CM/CMTS. -- docsTestCapability OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ability of this device to support the programmable features identified by the TYPE field from the CM/CMTS TLV table in [17]. Each octet within this octet string represents eight tests. For example, the first octet represents tests one through eight (with the msb representing test one) as identified by the TYPE field." ::= { docsTestBaseObjects 1 } docsTestStatus OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current operating status of tests initiated through the docsTestSetupObjects. The octet representation is identical to that used by docsTestCapability. A bit representation of one indicates that a test is currently active, while zero indicates the test is inactive or has completed." ::= { docsTestBaseObjects 2 } -- -- docsTestSetupObjects -- -- These objects setup the test parameters ands initiate the test. docsTestType OBJECT-TYPE SYNTAX Integer32 (0..1023) MAX-ACCESS read-write STATUS current DESCRIPTION "Corresponds to the TYPE field from the CM/CMTS TLV Table in [17]. The default value of zero indicates no test has yet been initiated. A WrongValueError should be returned in response to a write request for a test not supported by the device. A read request will return the docsTestType value last successfully written, whether that test is active or inactive." DEFVAL { 0 } ::= { docsTestSetupObjects 1 } docsTestData OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "The OCTET STRING length and value correspond to the LENGTH and VALUE fields from the CM/CMTS TLV Table in [17]. A read request will return the docsTestData value last successfully written, whether that test is active or inactive." ::= { docsTestSetupObjects 2 } docsTestEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Used to initiate or stop the tests setup through the docsTestType and docsTestData objects. A CommitFailedError should be returned in response to a TRUE Write request if the values in docsTestType and docsTestData are incompatible, or a test could not be initiated for any other reason." ::= { docsTestSetupObjects 3 } -- Compliance statements docsTestConformance OBJECT IDENTIFIER ::= { docsTestMIB 2 } docsTestCompliances OBJECT IDENTIFIER ::= { docsTestConformance 1 } docsTestGroups OBJECT IDENTIFIER ::= { docsTestConformance 2 } docsTestBasicCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for devices that implement the DOCSIS compliant programmable test features." MODULE -- docsTestMib -- unconditionally mandatory groups MANDATORY-GROUPS { docsTestGroup } ::= { docsTestCompliances 1 } docsTestGroup OBJECT-GROUP OBJECTS { docsTestCapability, docsTestStatus, docsTestType, docsTestData, docsTestEnable } STATUS current DESCRIPTION "Group of objects implemented in both Cable Modems and Cable Modem Termination Systems." ::= { docsTestGroups 1 } END